Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Takuya Okada Masato Yamaguchi Atsushi Kitagawa Ryota Kawasaki Yoshikatsu Nomura Yutaka Okita Kazuro Sugimura Koji Sugimoto
  • چاپ و سال / کشور: 2010

Description

Purpose To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stentgrafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrastenhanced CT was performed in seven patients with chronic kidney disease. Results All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p\0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement
Cardiovasc Intervent Radiol Received: 26 October 2010 / Accepted: 2 December 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری