Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate  Management Option?

Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Jessica M. Langer Raphael M. Cohen Jeffrey S. Berns Jesse Chittams Emily T. Cooper Scott O. Trerotola
  • چاپ و سال / کشور: 2010

Description

Purpose Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Grampositive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcusinfected tunneled dialysis catheters compared with nonstaphylococcus- infected tunneled dialysis catheters. Methods Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase- negative staphylococcus not otherwise specified. Control patients (n = 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.
Cardiovasc Intervent Radiol DOI 10.1007/s00270-011-0180-4 Received: 9 August 2010 / Accepted: 3 December 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری