ModiWed minimally invasive approach for dynamic hip screw Wxation
- نوع فایل : کتاب
- زبان : انگلیسی
- مؤلف : Mayank Agrawal · P. Yuvarajan · Lalit Maini
- چاپ و سال / کشور: 2010
Description
Intertrochanteric fracture is a common injury of increasing geriatric population. Dynamic hip screw (DHS) is one of the commonly used implants used for the internal Wxation of intertrochanteric fractures. Use of standard plate by a minimally invasive technique is both possible and advantageous to patient outcome in these fractures by allowing a smaller incision, a shorter surgical time, decreased operative blood loss and less postoperative pain. All these factors in turn will reduce the duration of hospital stay and improve the healing and rehabilitation potential of the elderly patients. In this article, we describe a modiWcation of standard technique for DHS Wxation with a clinical follow-up of 40 consecutive cases, all having satisfactory outcome.
Eur J Orthop Surg Traumatol (2011) 21:375–379 DOI 10.1007/s00590-010-0719-0 Received: 10 July 2010 / Accepted: 15 October 2010 / Published online: 11 November 2010