Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae

Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Dong-Ho Lee • Sung-Woo Lee • Suk Jung Kang • Chang Ju Hwang • Nam Heun Kim • Ju-Yul Bae • Yung-Tae Kim • Choon Sung Lee • K. Daniel Riew
  • چاپ و سال / کشور: 2011

Description

The present study was performed to determine the optimal entry points and trajectories for cervical pedicle screw insertion into C3–7. The study involved 40 patients (M:F = 20:20) with various cervical diseases. A surgical simulation program was used to construct three-dimensional spine models from cervical spine axial CT images. Axial, sagittal, and coronal plane data were simultaneously processed to determine the ideal pedicle trajectory (a line passing through the center of the pedicle on coronal, sagittal, and transverse CT images). The optimal entry points on the lateral masses were then identified. Horizontal offsets and vertical offsets of the optimal entry points were measured from three different anatomical landmarks: the lateral notch, the center of the superior edge and the center of lateral mass. The transverse angle and sagittal angles of the ideal pedicle trajectory were measured. Using those entry points and trajectory results, virtual screws were placed into the pedicles using the simulation program, and the outcomes were evaluated. We found that at C3–6, the optimal entry point was located 2.0–2.4 mm medial and 0–0.8 mm inferior to the lateral notch. Since the difference of 1 mm is difficult to discern intra-operatively, for ease of remembrance, we recommend rounding off our findings to arrive at a starting point for the C3–6 pedicle screws to be 2 mm directly medial to the lateral notch. At C7, by contrast, the optimal entry point was 1.6 mm lateral and 2.5 mm superior to the center of lateral mass. Again, for ease of remembrance, we recommend rounding off these numbers to use a starting point for the C7 pedicle screws to be 2 mm lateral and 2 mm superior to the center of lateral mass. The average transverse angles were 45 at C3–5, 38 at C6, and 28 at C7. The entry points for each vertebra should be adjusted according to the transverse angles of pedicles. The mean sagittal angles were 7 upward at C3, and parallel to the upper end plate at C4–7. The simulation study showed that the entry point and ideal pedicle trajectory led to screw placements that were safer than those used in other studies.
Eur Spine J (2011) 20:905–911 DOI 10.1007/s00586-010-1655-8 Received: 4 June 2010 / Revised: 17 November 2010 / Accepted: 5 December 2010 / Published online: 9 April 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری