Repeatability of intra-ocular pressure and central corneal  thickness measurements provided by a non-contact  method of tonometry and pachymetry

Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Domenico Schiano Lomoriello & Marco Lombardo & Laura Tranchina & Francesco Oddone & Sebastiano Serrao & Pietro Ducoli
  • چاپ و سال / کشور: 2010

Description

Background To examine the repeatability of intra-ocular pressure (IOP) and central corneal thickness (CCT) measurements provided by the Tono-Pachymeter NT530P (Nidek, Japan), and to assess agreement of the device with Goldmann applanation tonometry (GAT) and ultrasound pachymetry (UP). Methods Sixty-two normal eyes of 62 subjects were included in the study. Three sessions of measurements, each consisting of three sets of measurements, were completed with each device. Repeatability was determined with the coefficient of variation (CoV) and the coefficient of repeatability (CoR) values. Agreement between devices was examined by Bland–Altman analysis and intraclass correlation coefficient (ICC) analyses. Results The CoV and CoR for IOP values were 18.4% and 5.5 mmHg with the NT530P and 16.6% and 4.3 mmHg with the GAT respectively. On average, NT530P overestimated the IOP compared with GAT by 1.3 mmHg. The 95% limits of agreement between the methods ranged from .5.9 to +3.3 mmHg, and the ICC for average IOP measures between devices was 0.64 (P<0.001). The CoV and CoR for CCT measurements were 5.5% and 59.8 ìm with the NT530P and 5.5% and 60.5 ìm with UP. NT530P CCT readings were on average 13 ìm thinner than those obtained with UP. The 95% limits of agreement (LoA) ranged from .7.4 to +33.1 ìm, and the ICC for average CCT measures between devices was 0.93 (P<0.001). Conclusion The NT530P demonstrated high IOP and CCT measurement repeatability in the normal population studied. The device tended to slightly overestimate IOP compared to GAT. CCT values provided by NT530P were interchangeable with those of UP
Graefes Arch Clin Exp Ophthalmol (2011) 249:429–434 DOI 10.1007/s00417-010-1550-3 Received: 8 July 2010 / Revised: 5 October 2010 / Accepted: 10 October 2010 / Published online: 28 October 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری