Reproducibility of straylight measurement by C-Quant  for assessment of retinal straylight using the compensation  comparison method

Reproducibility of straylight measurement by C-Quant for assessment of retinal straylight using the compensation comparison method

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Ivo Guber & Lucas M. Bachmann & Josef Guber & Frank Bochmann & Alex P. Lange & Michael A. Thiel
  • چاپ و سال / کشور: 2011

Description

Background Straylight gives the appearance of a veil of light thrown over a person’s retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects’ age. Participants and Methods Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21–59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. Results The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85–1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p<0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p=0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p=0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p=0.09) were observed in subjects with blue irises as compared to darkcolored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). Conclusions Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.
Graefes Arch Clin Exp Ophthalmol DOI 10.1007/s00417-011-1704-y Received: 13 December 2010 / Revised: 29 March 2011 / Accepted: 30 March 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری