Effect of the lower limb rotational alignment on tibiofemoral  contact pressure

Effect of the lower limb rotational alignment on tibiofemoral contact pressure

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Mohamed Kenawey • Emmanouil Liodakis • Christian Krettek • Sven Ostermeier • Tatiana Horn • Stefan Hankemeier
  • چاپ و سال / کشور: 2011

Description

Purpose The effect of the rotational alignment of lower extremities on the tibiofemoral contact mechanics is not known. This study was designed to measure the contact area and pressure within medial and lateral tibiofemoral compartments following controlled serial rotational deformities through femoral and tibial shafts. Methods Eight lower extremities of fresh frozen cadavers were used. Computed tomography was conducted to measure the rotational profile of the lower extremities. Through a medial parapatellar arthrotomy, pressure sensors were implanted into both tibiofemoral compartments. Femoral and tibial mid-shaft osteotomies were performed and stabilized by non-locked intramedullary nails and external fixators in neutral rotation. The contact area and pressure were measured under axial loading in neutral rotation and following serial malrotations from 40 external to 40 internal malrotation in 10 increments. Results Contact area was not affected by malrotations. Medial compartment contact pressure rose with external and decreased with internal malrotations whether femoral or tibial (P\0.0001) while lateral pressure was not affected. When correlated with the cadavers’ original rotational profile, decreased femoral neck anteversion was associated with increased medial pressure up to 28.5% at 20 of retroversion while it decreased with increased anteversion. On the other hand, decreased tibial torsion angle was associated with decreased medial pressure up to -32% at 10 of internal torsion and it increased with excessive external torsion. Furthermore, there was a strong positive correlation with the total rotational alignment as measured by the neck malleolar angle. Conclusion A significant interaction could be detected between the rotational alignment of the lower extremit
Knee Surg Sports Traumatol Arthrosc DOI 10.1007/s00167-011-1482-4 Received: 16 April 2010 / Accepted: 15 March 2011
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری