Accuracy and reproducibility of a novel semi-automatic  segmentation technique for MR volumetry  of the pituitary gland

Accuracy and reproducibility of a novel semi-automatic segmentation technique for MR volumetry of the pituitary gland

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • مؤلف : Diane M. Renz & Horst K. Hahn & Peter Schmidt & Jan Rexilius & Markus Lentschig & Alexander Pfeil & Dieter Sauner & Clemens Fitzek & Hans-Joachim Men
  • چاپ و سال / کشور: 2011

Description

Introduction Although several reports about volumetric determination of the pituitary gland exist, volumetries have been solely performed by indirect measurements or manual tracing on the gland’s boundaries. The purpose of this study was to evaluate the accuracy and reproducibility of a novel semi-automatic MR-based segmentation technique. Methods In an initial technical investigation, T1-weighted 3D native magnetised prepared rapid gradient echo sequences (1.5 T) with 1 mm isotropic voxel size achieved high reliability and were utilised in different in vitro and in vivo studies. The computer-assisted segmentation technique was based on an interactive watershed transform after resampling and gradient computation. Volumetry was performed by three observers with different software and neuroradiologic experiences, evaluating phantoms of known volume (0.3, 0.9 and 1.62 ml) and healthy subjects (26 to 38 years; overall 135 volumetries). Results High accuracy of the volumetry was shown by phantom analysis; measurement errors were <4% with a mean error of 2.2%. In vitro, reproducibility was also promising with intra-observer variability of 0.7% for observer 1 and 0.3% for observers 2 and 3; mean interobserver variability was in vitro 1.2%. In vivo, scan–rescan, intra-observer and inter-observer variability showed mean values of 3.2%, 1.8% and 3.3%, respectively. Unifactorial analysis of variance demonstrated no significant differences between pituitary volumes for various MR scans or software calculations in the healthy study groups (p>0.05). Conclusion The analysed semi-automatic MR volumetry of the pituitary gland is a valid, reliable and fast technique. Possible clinical applications are hyperplasia or atrophy of the gland in pathological circumstances either by a single assessment or by monitoring in follow-up studies.
Neuroradiology (2011) 53:233–244 DOI 10.1007/s00234-010-0727-0 Received: 27 February 2010 / Accepted: 28 May 2010 / Published online: 19 June 2010
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری