ارزیابی تاثیر ویژگی های طراحی برج خنک کننده بر روی محیط نزدیک میدان / Evaluation of impacts of cooling tower design properties on the near-field environment

ارزیابی تاثیر ویژگی های طراحی برج خنک کننده بر روی محیط نزدیک میدان Evaluation of impacts of cooling tower design properties on the near-field environment

  • نوع فایل : کتاب
  • زبان : انگلیسی
  • ناشر : Elsevier
  • چاپ و سال / کشور: 2018

توضیحات

رشته های مرتبط مهندسی مکانیک
گرایش های مرتبط تاسیسات حرارتی برودتی
مجله مهندسی و طراحی هسته ای – Nuclear Engineering and Design
دانشگاه Advanced Reactor Development Lab – Korea Hydro & Nuclear Power Co – Republic of Korea

منتشر شده در نشریه الزویر
کلمات کلیدی برج خنک کننده، ارزیابی محیط زیست، مدل SACTI، نیروگاه هسته ای

Description

1. Introduction Since 1980, in the United States, closed-cycle cooling design such as in cooling towers has been applied to most new nuclear power plants on account of environmental regulations and policies relating to the effect of the increased temperature of discharged water on the environment, the impact of the cooling intake structures on underwater organisms, and fresh water availability (EPRI, 2012). However, plumes from cooling towers can generate adverse impacts on the environment such as through plume shadowing, water and salt deposition, ground level fogging and icing, and solar energy loss, among others (Davis, 1998; U.S. NRC, 2007). The environmental impact of cooling towers operating on the plant site can be investigated by measurement devices placed near the cooling tower region. On the other hand, the evaluation of the environmental impact of a cooling tower under construction or to be constructed in the future should be conducted through experiment or numerical analysis based on past meteorological information. Full-scale experiments for predicting the dynamic behavior of cooling tower plumes are expensive; scale model experiments (Michioka et al., 2007; Ruiz et al., 2016) have their limitations; therefore, many studies (Carhart and Policastro, 1991; Carhart et al., 1992; Orville et al., 1980; Moore, 1977) on the environmental impact of cooling towers have focused on developing an analytical plume prediction model. Policastro et al. (1981a) developed an improved mathematical model, more wellknown as the seasonal/annual cooling tower impact (SACTI) model, for predicting plume and drift behavior occurring from cooling towers. They also developed a user manual of the improved mathematical model (Policastro et al., 1984) and updated it in terms of user friendliness (Dunn et al., 1987). The single plume behavior using the SACTI model was tested and validated with data from the Chalk Point Dye Tracer Study (Policastro et al., 1981a). The behavior of multiple plumes using the SACTI model was also validated against the multiple unit cooling towers at Pittsburgh, CA (Policastro et al., 1981b). The original SACTI code has been available in public domain and accepted by both the United States Environmental Protection Agency (U.S. EPA) and the United States Nuclear Regulatory Commission (U.S. NRC) (EPRI, 2015). Due to recent advances in computational fluid dynamics (CFD) techniques, studies (Lucas et al., 2010; Meroney, 2008; Chahine et al., 2015; Milosavljevic and Heikkilä, 2001) have been carried out to apply CFD techniques to the environmental assessment of a cooling tower, yielding predictions of more detailed accurate plume behaviors.
اگر شما نسبت به این اثر یا عنوان محق هستید، لطفا از طریق "بخش تماس با ما" با ما تماس بگیرید و برای اطلاعات بیشتر، صفحه قوانین و مقررات را مطالعه نمایید.

دیدگاه کاربران


لطفا در این قسمت فقط نظر شخصی در مورد این عنوان را وارد نمایید و در صورتیکه مشکلی با دانلود یا استفاده از این فایل دارید در صفحه کاربری تیکت ثبت کنید.

بارگزاری