# عنوان نوع فایل سایز فایل بازدید دانلود امتیاز قیمت (تومان)
1
Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility
218.27 KB 83 1
رایگان
2
Tears at the rotator cuff footprint: Prevalence and imaging characteristics in 305 MR arthrograms of the shoulder
342.18 KB 57 0
رایگان
3
PET/CT without capacity limitations: a Danish experience from a European perspective
308.45 KB 70 0
رایگان
4
64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement
288.87 KB 72 1
رایگان
5
Letter to the editor re: molecular imaging in oncology: the acceptance of PET/CT and the emergence of MR/PET imaging
220.83 KB 152 0
رایگان
6
Renal artery stenosis: comparative assessment by unenhanced renal artery mra versus contrast-enhanced MRA
278.32 KB 71 0
رایگان
7
Multidetector-CT angiography in pulmonary embolism—can image parameters predict clinical outcome?
175.16 KB 72 0
رایگان
8
Prediction and monitoring of the response to chemoradiotherapy in oral squamous cell carcinomas using a pharmacokinetic analysis based on the dynamic contrast-enhanced MR imaging findings
512.54 KB 75 0
رایگان
9
Feasibility of dynamic MRI for evaluating velopharyngeal insufficiency in children
529.55 KB 67 0
رایگان
10
Distinguishing benign from malignant parotid gland tumours: low-dose multi-phasic CT protocol with 5-minute delay
260.42 KB 74 0
رایگان
11
Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA
441.75 KB 69 0
رایگان
12
Value of MRI and diffusion-weighted MRI for the diagnosis of locally recurrent rectal cancer
401.71 KB 93 0
رایگان
13
Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism – correlation with D-dimer level, right heart strain and clinical outcome
260.79 KB 62 0
رایگان
14
A new kaolin-based haemostatic bandage compared with manual compression for bleeding control after percutaneous coronary procedures
140.34 KB 71 0
رایگان
15
Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor
485.38 KB 82 0
رایگان
16
Computed tomography—old ideas and new technology
550.29 KB 74 0
رایگان
17
Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis
369.42 KB 59 0
رایگان
18
Dual-energy CT angiography in peripheral arterial occlusive disease—accuracy of maximum intensity projections in clinical routine and subgroup analysis
346.54 KB 58 0
رایگان
19
Contribution of the hepatobiliary phase of Gd-EOB-DTPAenhanced MRI to Dynamic MRI in the detection of hypovascular small (.2 cm) HCC in cirrhosis
462.15 KB 74 0
رایگان
20
Accuracy of coronary artery stenosis detection with CT versus conventional coronary angiography compared with composite findings from both tests as an enhanced reference standard
311.53 KB 61 0
رایگان
21
Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques
538.63 KB 63 0
رایگان
22
Outcome analysis in 3,160 implantations of radiologically guided placements of totally implantable central venous port systems
219.38 KB 60 0
رایگان
23
Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients
325.77 KB 69 0
رایگان
24
Diagnostic value of 3D contrast-enhanced magnetic resonance angiography in Takayasu’s arteritis—a comparative study with digital subtraction angiography
444.00 KB 65 0
رایگان
25
Feasibility of simultaneous PET/MR imaging in the head and upper neck area
438.37 KB 75 0
رایگان
Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

Optimising diffusion weighted M ...

Objectives To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelom ...

دانلود 1
218.27 KB
رایگان
Tears at the rotator cuff footprint: Prevalence and imaging characteristics in 305 MR arthrograms of the shoulder

Tears at the rotator cuff footp ...

Objectives To evaluate the prevalence, imaging characteristics and anatomical distribution of tears at the rotator cuff (RC) footprint with MR arthr ...

342.18 KB
رایگان
PET/CT without capacity limitations: a Danish experience from a European perspective

PET/CT without capacity limitat ...

Objectives We report the 3-year clinical experience of a large new Danish PET/CT centre without capacity limitations in relation to national and Eur ...

308.45 KB
رایگان
64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol  for improved vascular and parenchymal contrast enhancement

64-section multidetector CT of ...

Objectives To prospectively investigate the effect of varying the injection flow rates of a saline chaser on vascular and parenchymal contrast enhan ...

دانلود 1
288.87 KB
رایگان
Letter to the editor re: molecular imaging in oncology: the acceptance of PET/CT and the emergence  of MR/PET imaging

Letter to the editor re: molecu ...

Recently, Schiepers et al. [1] have illuminated the emerging field of MR/PET imaging and its expected great potential. We are in agreement with the ...

220.83 KB
رایگان
Renal artery stenosis: comparative assessment by unenhanced renal artery mra versus contrast-enhanced MRA

Renal artery stenosis: comparat ...

Objectives To evaluate steady-state free precession (SSFP) non-contrast-enhanced MR angiography (Unenhanced-MRA) versus conventional contrast-enhanc ...

278.32 KB
رایگان
Multidetector-CT angiography in pulmonary embolism—can image parameters predict clinical outcome?

Multidetector-CT angiography in ...

Objective To assess if pulmonary CT angiography (CTA) can predict outcome in patients with pulmonary embolism (PE). Methods Retrospective analysis o ...

175.16 KB
رایگان
Prediction and monitoring of the response to chemoradiotherapy in oral squamous cell carcinomas  using a pharmacokinetic analysis based on the dynamic contrast-enhanced MR imaging findings

Prediction and monitoring of th ...

Objectives To evaluate whether a pharmacokinetic analysis is useful for both predicting and monitoring the response to chemoradiotherapy (CRT) in or ...

512.54 KB
رایگان
Feasibility of dynamic MRI for evaluating velopharyngeal insufficiency in children

Feasibility of dynamic MRI for ...

Objective To demonstrate the feasibility of dynamic MRI with near-real-time temporal resolution for analysing velopharyngeal closure. Methods Eleve ...

529.55 KB
رایگان
Distinguishing benign from malignant parotid gland tumours: low-dose multi-phasic CT protocol  with 5-minute delay

Distinguishing benign from mali ...

Objectives To explore the percentage enhancement washout ratio (PEW) and relative PEW (RPEW) of low-dose multi-phasic computed tomography (CT) in di ...

260.42 KB
رایگان
Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA

Magnetic resonance angiography ...

Objectives To compare 3D non-enhanced ECG-gated inflow-dependent MRA (NE-MRA) vs. continuous table movement (CTM) MR-angiography and time-resolved ...

441.75 KB
رایگان
Value of MRI and diffusion-weighted MRI for the diagnosis of locally recurrent rectal cancer

Value of MRI and diffusion-weig ...

Objectives To evaluate the accuracy of standard MRI, diffusion-weighted MRI (DWI) and fusion images for the diagnosis of locally recurrent rectal ca ...

401.71 KB
رایگان
Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism – correlation with D-dimer level, right heart strain and clinical outcome

Dual energy CT pulmonary blood ...

Objective To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart stra ...

260.79 KB
رایگان
A new kaolin-based haemostatic bandage compared with manual compression for bleeding control  after percutaneous coronary procedures

A new kaolin-based haemostatic ...

Objective Bleeding and vascular access site complications are an important cause of morbidity after percutaneous femoral procedures. New haemostatic ...

140.34 KB
رایگان
Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

Feasibility of diffusion tensor ...

Objectives To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional ...

485.38 KB
رایگان
Computed tomography—old ideas and new technology

Computed tomography—old ideas a ...

Several recently introduced ‘new’ techniques in computed tomography—iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT— ...

550.29 KB
رایگان
Influence of coronary artery disease prevalence on predictive values of coronary CT angiography:  a meta-regression analysis

Influence of coronary artery di ...

Objective To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. Methods We perfor ...

369.42 KB
رایگان
Dual-energy CT angiography in peripheral arterial occlusive disease—accuracy of maximum intensity projections in clinical routine and subgroup analysis

Dual-energy CT angiography in p ...

Objective To evaluate the accuracy of dual-energy CT angiography (DE-CTA) maximum intensity projections (MIPs) in symptomatic peripheral arterial oc ...

346.54 KB
رایگان
Contribution of the hepatobiliary phase of Gd-EOB-DTPAenhanced MRI to Dynamic MRI in the detection  of hypovascular small (.2 cm) HCC in cirrhosis

Contribution of the hepatobilia ...

Objective To prospectively assess the additional value of the hepatobiliary (HB) phase of Gd-EOB-DTPA-MRI in identifying and characterising small (. ...

462.15 KB
رایگان
Accuracy of coronary artery stenosis detection with CT versus conventional coronary angiography  compared with composite findings from both tests as an enhanced reference standard

Accuracy of coronary artery ste ...

Objective To prospectively compare the accuracy of coronary CT angiography (CCTA) and conventional coronary angiography (CCA) for stenosis detection ...

311.53 KB
رایگان
Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques

Magnetic resonance angiography ...

Objective To compare different techniques for carotid imaging including contrast-enhanced, unenhanced and dynamic techniques to find an alternative ...

538.63 KB
رایگان
Outcome analysis in 3,160 implantations of radiologically guided placements of totally implantable central venous port systems

Outcome analysis in 3,160 impla ...

Objectives In this retrospective study the success and complication rates after radiologically guided port catheter implantation were evaluated. Me ...

219.38 KB
رایگان
Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients

Systolic prospectively ECG-trig ...

Objectives To assess feasibility, image quality, and radiation dose of prospectively ECG-triggered coronary CT angiography (CTA) in orthotopic heart ...

325.77 KB
رایگان
Diagnostic value of 3D contrast-enhanced magnetic resonance angiography in Takayasu’s arteritis—a comparative study with digital subtraction angiography

Diagnostic value of 3D contrast ...

Objective To assess the diagnostic value of 3D CEMRA in TA compared with DSA. Methods Twenty-two patients with clinically suspected TA based on 199 ...

444.00 KB
رایگان
Feasibility of simultaneous PET/MR imaging in the head and upper neck area

Feasibility of simultaneous PET ...

Objective The aim of this pilot study was to test and demonstrate the feasibility of simultaneous positron emission tomography (PET) and magnetic re ...

438.37 KB
رایگان

بارگزاری